Siemens Earth leakage circuit breaker C16 1p+N 0.03A A 5SU1326-7FP16
This page always stays fresh and updates automatically.
FI/LS switch, 6 kA, 2P Type A, 30 mA, C-Characteristic, In: 16A Un: 230V. SENTRON 5SU1 FI/LS switch for combined protection against overload, short circuit, and fault currents. Our FI/LS switches (RCBO) are VDE tested and certified according to DIN EN 61009-1, DIN EN 61009-2-1. With their double-chamber terminals, connecting conductors of different cross-sections is very easy. Other Siemens SENTRON protective devices can be quickly and easily connected with the 5ST3 busbars. The data matrix code on the device provides quick access to all technical data in the Siemens Industry Online Support App. SENTRON protective devices can be expanded with a wide range of functions using the continuous accessories from the system modular kit. Optimal technology for your safety - only from Siemens.

Siemens Earth leakage circuit breaker C16 1p+N 0.03A A 5SU1326-7FP16
Residual current circuit breaker 3X 1PN 6kA B-10A 30mA Type QuickConnect. Residual current circuit breaker according to DIN EN61009-1 VDE 0664-20 with a single-pole circuit breaker for 230 AC circuits and a residual current protection circuit in a compact housing. QuickConnect terminal according to DIN EN 60898-1 VDE 0641-11, with a load capacity of up to 16 A at the output and up to 63 A at the input, blue test button and residual current indicator. Easy individual removal from the phase rail assembly. Suitable for retrofitting additional devices. Labeling option directly on the device. ADZ310D.

Hager Helicopter 3 + N AC Switch B 10A 0.03A Type A 6kA Type RCBO (ADZ310D)
The Hager CDA516D is a highly advanced residual current circuit breaker designed for use in electrical installations. With a rated current of 16 A and a type A tripping characteristic, this 2-pole RCD provides reliable protection against fault currents up to 30 mA. It meets the requirements of DIN EN 61008-2-1 and VDE 0664 parts 10 and 11, making it a safe choice for various applications. The CDA516D is suitable for mounting on a DIN rail, allowing for easy installation without additional tools. The connection terminals are equipped with wire insertion protection, which facilitates handling and enhances safety. Additionally, the switch features an external test button for quick functionality checks. With its robust design and high safety standards, the Hager CDA516D is a valuable addition to any electrical installation.
- Residual current circuit breaker with 10 kA short-circuit strength
- Easy installation without tools thanks to the retrofitting of additional devices
- Wire insertion protection on the connection terminals for increased safety
- External test button for quick functionality checks
- Suitable for use in residential and commercial installations.

Siemens circuit breaker 5SL6616-7
Manufacturer: Siemens
Designation: Circuit breaker 400V 6kA 3+N C 16A
Type: 5SL6616-7
Installation depth: 70 mm
Tripping characteristic: C
Number of poles (total): 4
Number of protected poles: 3
Rated current: 16 A
Rated voltage: 400 V
Rated short-circuit capacity Icn according to EN 60898 at 230 V: 6 kA
Voltage type: AC
Rated short-circuit capacity Icn according to EN 60898 at 400 V: 6 kA
Rated short-circuit capacity Icu according to IEC 60947-2 at 230 V: 6 kA
Rated short-circuit capacity Icu according to IEC 60947-2 at 400 V: 6 kA
Frequency: 50 Hz
Energy limitation class: 3
Flush-mounted: no
Switching neutral conductor: yes
Overvoltage category: 3
Degree of pollution: 2
Additional devices possible: yes
Width in division units: 4
Protection class (IP): IP20
Ambient temperature during operation: -25 to 45 °C
Connectable conductor cross-section multi-stranded: 0.75 to 25 mm²
Connectable conductor cross-section single-stranded: 0.75 to 25 mm²
Explosion-proof: no
The SENTRON 5SL circuit breaker provides reliable short-circuit and overload protection for standard applications in residential and commercial buildings. The device can be mounted and dismounted without tools. The wiring of the supply is made easy by the rear-mounted busbar. The 5SL circuit breakers are available in various versions, including 1-, 2-, 3-, 4-, as well as 1+N and 3+N pole variants and other special types. A wide range of accessories, such as auxiliary switches, allows for diverse functional expansions. Simply safe with SENTRON protection devices.

Siemens Circuit Breaker 5SL6525-7
Manufacturer: Siemens
Designation: Circuit breaker 230V 6kA 1+N C 25A
Type: 5SL6525-7
Installation depth: 70 mm
Tripping characteristic: C
Number of poles (total): 2
Number of protected poles: 1
Rated current: 25 A
Rated voltage: 230 V
Rated short-circuit capacity Icn according to EN 60898 at 230 V: 6 kA
Voltage type: AC
Rated short-circuit capacity Icn according to EN 60898 at 400 V: 6 kA
Rated short-circuit capacity Icu according to IEC 60947-2 at 230 V: 6 kA
Rated short-circuit capacity Icu according to IEC 60947-2 at 400 V: 6 kA
Frequency: 50 Hz
Energy limiting class: 3
Flush-mounted: no
Switching neutral conductor: yes
Overvoltage category: 3
Degree of pollution: 2
Additional devices possible: yes
Width in division units: 2
Protection class (IP): IP20
Ambient temperature during operation: -25 to 45 °C
Connectable conductor cross-section multi-stranded: 0.75 to 25 mm²
Connectable conductor cross-section single-stranded: 0.75 to 25 mm²
Explosion-proof: no
Siemens Circuit Breaker 5SL6525-7: additional details
Circuit breaker 230V 6kA, 1+N-pole, C, 25A.
SENTRON 5SL circuit breakers provide safe short-circuit and overload protection for standard applications in residential and commercial buildings. Tool-free installation and removal of the device. Easy wiring of the supply through the rear-mounted busbar. The 5SL circuit breakers are available in 1-, 2-, 3-, 4-, as well as 1+N and 3+N pole versions, along with other special types. The extensive accessories, such as auxiliary switches, allow for versatile function expansion. Simply safe with SENTRON protection devices.

Siemens Miniature circuit breaker 5SL6525-7 1 pc.
The HAG ADS970D Fi-LS 1P+N 6kA C-20A 30mA Type A QC is a highly advanced residual current circuit breaker designed for use in electrical installations. With a rated voltage of 240 volts and a rated current of 20 amperes, this device provides reliable protection against fault currents and overloads. The switch is equipped with a QuickConnect terminal, allowing for easy and quick installation. It meets the requirements of DIN EN 61009-1 and offers touch protection in accordance with DIN VDE 0106 Part 100. The blue test button and fault current indicator ensure user-friendly handling and easy maintenance. The HAG ADS970D is suitable for flush mounting and allows for straightforward individual removal from the phase rail connection, increasing flexibility during installation. Additionally, it offers the possibility of retrofitting additional devices and is marked with a VDE symbol, underscoring its quality and safety.
- QuickConnect terminal for easy installation
- Touch protection according to DIN VDE 0106 Part 100
- Blue test button for simple functionality testing
- Suitable for retrofitting additional devices
- Easy individual removal from the phase rail connection.

The Doepke GmbH RCD DFS4 040-4/0.03A 500 is a highly advanced residual current device designed for use in single-phase and three-phase networks. This switch provides reliable protection for people, animals, and electrical systems by automatically disconnecting the power supply in the event of dangerously high fault currents. With a compact design that occupies only four modular units, the DFS4 is suitable for both standard applications and specific requirements. The devices are available in various versions and offer high short-circuit resistance as well as the ability to connect large conductor cross-sections via the double-decker terminals on both sides. The integrated switching position indicator and the viewing window for labeling stickers facilitate handling and maintenance. The multifunctional switch knob allows for easy operation and troubleshooting, making this RCD a practical choice for various electrical installations.
- Two- or four-pole design for flexible applications
- Network and auxiliary voltage-independent tripping for increased safety
- Sensitivity for alternating and pulsating direct fault currents (Type A)
- High short-circuit resistance for reliable operation
- Easy mounting on DIN rail with wide double-decker terminals.

Doepke GmbH RCD switch DFS4 040-4/0.03A 500
RCBOs combine residual current and circuit breakers in one device (RCCB/MCCB combination). They protect people from fault currents and installations from short circuits and overloads. The DRCBO 4 has a rated breaking capacity of 6 kA. In addition to a tripped indicator, it also features a labeling window. Type A switches are sensitive to pulsating and alternating currents. This function is independent of the mains voltage. Switches with characteristic B are the standard protection for lighting and socket circuits. Standard switches are designed for circuits with a rated voltage of 230 V or 400 V and a rated frequency of 50 Hz.
Features: pulsating and alternating current sensitivity, mains voltage-independent tripping, compact size for all rated currents, switching position indicator, separate indication of the tripping reason, terminal blocks with a wide clamping cross-section range on both connection sides, neutral conductor on the right, labeling window, mounting type: quick fastening on mounting rail, installation position arbitrary, power supply arbitrary.
Applications: Protection of circuits in residential and commercial buildings as well as industrial plants with TN-S, TT, and TN-C-S networks. In IT networks, RCCB/MCCB switches can be used for disconnection in the event of a second earth fault. Use in systems with TN-C networks and for the protection of circuits where power electronics devices can cause smooth direct fault currents or fault currents with frequencies other than 50/60 Hz is excluded.

The S 200 series circuit breakers protect cables and wires from overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN 60947-2, and UL 1077. Their patented terminal block ensures easy and secure connection and handling through a pressure plate. For better visibility during wiring, the connection opening for wires is located above the connection opening for the phase rail. Conductor cross-sections of up to 35 mm² can be directly connected to the device via the terminal block with insulation in protection class IP20. The extensive range of accessories provides everything you need for your installation tasks. Numerous approvals make the S 200 suitable for worldwide use. Each device undergoes three intensive tests for quality and performance before delivery.

FI residual current circuit breaker, 2-pole, Type F, time-delayed, In: 25 A, 30 mA, Un AC: 230 V. The residual current circuit breaker is the protective device for touch protection. Siemens' patented residual current protective devices are an important component of the SENTRON protection systems for electrical installations, as they prevent life-threatening electrical accidents by safely disconnecting dangerous fault currents to ground. Electrically ignited fires can be prevented right from the start. Whether through direct contact with live parts or through indirect contact with operating equipment, protection is primarily achieved through rapid disconnection. The Siemens FI circuit breakers 5SV stand out for: 1. Comprehensive protection for people and property against electric shock 2. Whether sinusoidal alternating fault currents or smooth direct fault currents - Siemens offers the right type for all requirements, as well as special versions.